Paradox Community

Items in pnews.paradox-programming

Subject:Re: installation question
Date:Thu, 10 Aug 2017 15:02:10 -0400
From:"Steven Green" <greens@diamondsg.com>
Newsgroups:pnews.paradox-programming
wow.. hers is the A960, not the A920, but otherwise it's the exact same 
thing !!

C:\Windows\twain_32\Dell\AIO Printer A960\dlbftwds.ds

there must be a reason it's the same


--

Steven Green
Myrtle Beach, South Carolina, USA

http://www.OasisTradingPost.com

Collectibles and Memorabilia
Vintage Lego Sets and Parts
- and Paradox support, too

"Kevin Baker"  wrote in message news:5989f629$1@pnews.thedbcommunity.com...

Steven,

I had a similar situation where whenever I tried to run my application or
just the runtime, I would get a GPV.  Here's what I did that fixed it for
me.
Download the Process Explorer from Microsoft
(https://docs.microsoft.com/en-us/sysinternals/downloads/process-explorer)
Run Paradox and get the GPV, don't exit Paradox, just let the GPV run.
Open Process Explorer and right-click on the pdxrwn32.exe entry and select
Properties, Look in the Current Directory field.  For the computer that was
having the entry it had: C:\Windows\twain_32\Dell\AIO Printer A920\ and the
client didn't even have a printer like that installed.  I stopped the
printer spooler and deleted the printer driver AND the package using Printui
/s /t2 from the command line.  I restarted the printer spooler, ok'ed the
GPV and launched the application again.  Worked perfect.

Not sure if this is the same error or if someone else has had the problem,
but it's worth a try.

Kevin

"Steven Green"  wrote in message news:5989cd4b$1@pnews.thedbcommunity.com...

didn't try the runtime yet..


--

Steven Green
Myrtle Beach, South Carolina, USA

http://www.OasisTradingPost.com

Collectibles and Memorabilia
Vintage Lego Sets and Parts
- and Paradox support, too

"Kevin Baker"  wrote in message news:5989b411$1@pnews.thedbcommunity.com...

Steve,
Do you get the GPF when you try and run the runtime all by itself?

Kevin

"Steven Green"  wrote in message news:5988c364@pnews.thedbcommunity.com...

I'm grasping at straws here, folks.. I have a client with p8 running fine on
a machine, but I try to load p11 from suite x8 or p11 from suite x3, I'm
getting a generic "general protection fault" error.. I'm just trying to run
it clean on C drive, not using the network yet at all

the bde obviously is fine, cuz p8 uses it.. both p11 versions create a net
file before the GP, there are no lock files on the drive.. p8 is not open
when I try to run p11

this should be a total no-brainer, but it's not.. what am I missing ???


--

Steven Green
Myrtle Beach, South Carolina, USA

http://www.OasisTradingPost.com

Collectibles and Memorabilia
Vintage Lego Sets and Parts
- and Paradox support, too


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus 


Copyright © 2004 thedbcommunity.com